GAS MASK

MIRA Safety CM-6M Tactical Gas Mask – Full-Face Respirator for CBRN Defense

Combining premium features with superior mil-spec construction, MIRA Safety’s CM-6M CBRN tactical gas mask / full-face respirator protects your face, internal organs and respiratory system against a full spectrum of toxic industrial chemicals (TIC) and chemical warfare agents (CWA) including chemical, biological and nuclear threats such as radioactive dust, noxious gas, vaporized pollutants and more.

Key Features of the CM-6M Tactical Gas Mask:

  • 20-year shelf life
  • Compatible with the 3M Safety 6878 Spectacle Kit (sold separately)
  • Uses widely available NATO-standard, 40-mm filter cartridges
  • Trusted by police worldwide and government entities in the Czech Republic, Norway, Portugal, Chile, Saudi Arabia, Turkey, Kuwait, Latvia and Lebanon
  • Durable bromobutyl rubber construction (meets CBRN protection standards)
  • Full-face panoramic design with a large visor to enable a wide-angle view
  • Hypoallergenic inner mask prevents fogging, even under hard use 
  • Tested resistance to mustard gas penetration for nearly 30 hours
  • Helmet-compatible
  • Fits up to 2 standard 40-mm 1/7” NATO filter cartridges (widely available with varying protection levels)
  • Comes with a pre-installed hydration system and canteen
  • Compatible with CamelBak water bladders with a Type A or M adapter (not included)
  • Used for industrial, agricultural, law enforcement, professional rescue, specialized welding, construction and painting applications
  • Conforms to European quality and sustainability standards, marked with the CE symbol
  • Meets all requirements under EN 136:1998, Class III
  • Complies with all standards under EN 168 for impact protection, making this the perfect mask for riot control situations 
  • Carries MIRA Safety’s special 5-year manufacturer warranty
  • Manufactured in the Czech Republic

TECHNICAL SPECIFICATIONS

The CM-6M Tactical Gas Mask has a facepiece of tough bromobutyl rubber (CBRN-compliant) for maximum resistance to TIC/CWA contaminants. The full-face respirator’s inner mask is made from a special hypoallergenic compound that ensures excellent tightness and avoids exhaled air contact with the visor to prevent fogging. It also reduces carbon dioxide(CO2) content in the mask’s inner space, which together with its favorable inhalation/exhalation breathing resistance, decreases the physiological burden for the user—providing more comfortable and practical all-day use.

The integrated speech diaphragm ensures at least 95% intelligibility of speech, allowing for easy communication with other members of your party. The mask is equipped with a five-point rubber-textile head harness to ensure a snug and lasting fit.

The CM-6M CBRN gas mask is produced in one size. To ensure proper functioning, the user’s face must be smooth, free of facial hair, sideburns and other hindrances at the points of contact.

The tactical gas mask is compatible with the 3M Safety 6878 Spectacle Kit (sold separately), with simple installation for those who are vision impaired and prefer not to wear contacts. 

The filter is fitted to the mask by screwing to the left or right inhalation chamber. The unused chamber (without filter) is sealed with an inhalation chamber plug. It is necessary to ensure the plug is properly screwed and tightened. 

Inhalation chambers of the CM-6 mask are ONLY compatible with Rd 40 x 1/7” thread in accordance with the EN 148-1 standard.

Selection of a suitable filter depends on the type and concentration of anticipated toxic agent. The CM-6 tactical mask equipped with a TIC or CWA filter is only safe for use in an environment containing at least 19.5% oxygen. The principles of filter selection and application are described in the filter user guides.

The CM-6 tactical gas mask may be used in class 1 explosive environments only. The CM-6 mask meets all of the requirements for class 3 of the EN 136 standard. It’s a great choice for riot gear or as a riot control gas mask.

TECHNICAL DATA

560g95%
1 sizebromine-butyl rubber
min. 70%polycarbonate
min. 80%Rd 40 x 1/7″

Breathing resistance at 30l/min. air flow:

max. 30 Pamax. 60 Pa

 

STORAGE

The CM-6 tactical gas mask must be stored in a dark, cool and dust-free place free from sudden temperature changes. The storage room should be ventilated regularly. Temperatures may vary between 10°C and 25°C within relative humidity up to 65%. Full face gas masks must not be exposed to radiant heat or sunshine. Fuels, solvents, lubricants and other inflammable substances, including chemicals, must not be stored with masks. Moreover, there must not be any electrical machines or appliances that produce sparks or discharges during operation (ozone creation).

Avoid deformation of the rubber parts of the facepiece and internal CBRN gas mask during storage.

    gas-mask
    gas-mask-1-web
    gas-mask-2-web
    gas-mask-3-web
    gas-mask-5-web

    MIRA Safety VK-450 Smoke / Carbon Monoxide Filter Cartridges

    Due to a significant spike in demand, our lead times on all orders have been increased. There is currently a four-week lead time, and your order will be shipped in the sequence in which it was received. We appreciate your patience as we work through this. 

    Transform your gas mask into a reliable, fully functioning multiuse smoke hood with these VK-450 filters. Designed to overcome smoke & particulates (along with high concentrations of carbon monoxide), these advanced filters provide crucial hours of protection and clean air from some of the most common disasters faced by US citizens. Grab a few VK-450 filters for your family today!

    Key Features:

    • Proven design provides comprehensive protection from a wide range of NBC threats, smoke and particulates.
    • Smoke respirator mask filter can be used in environments with as little as 19.5% oxygen.
    • Can be used at temperatures ranging from -40°С to +40°С.
    • Protection from ammonia, acetonitrile, hydrogen fluoride, hydrogen chloride, sulfur dioxide, hydrogen sulfide, hydrogen cyanide, phosgene, chlorine, chloropicrin, nitrogen oxides.
    • Each filter is vacuum-sealed and clearly labeled with its expiration date.
    • Long-lasting 13.5-year shelf life.
    • Manufacturer’s warranty ensures filters perform to specifications.

     

    Turn Your Gas Mask into a Respirator for Smoke with the VK-450

    Wildfires are a constant threat to the Western United States—where thousands of citizens may be forced to evacuate at a moment’s notice through choking clouds of smoke and searing heat. Meanwhile, over 71,000 homes are lost in structure fires every year, according to studies from the National Fire Protection Association (NFPA). Yet, few own escape respirators or fire protection hoods.

    That means that fire poses an immediate threat to millions of unprepared American families. That’s where our VK-450 gas mask filters come in. 

    While most conventional gas masks and filters can protect you from hundreds of nuclear, biological and chemical threats, the VK-450 is one of just a few filters that can also protect you from carbon monoxide and minimize the risk of smoke inhalation. The VK-450 helps to convert CO into CO2, allowing you to breathe it out. So, instead of also keeping a single-use fire/smoke hood on hand, you can use your existing gas mask for smoke protection in case of a house fire or wildfire.

    Of course, these filters still provide full protection from NBC threats, and they sport a truly impressive 13.5-year shelf life. They come individually packaged and are easy to stack, store and manage. 

    If you’ve got a gas mask, or if you’re thinking about getting one, don’t overlook these flexible filters. Scroll down to check out the full details:

     VK-450 technical specifications are as follows:

    – initial filter resistance to constant airflow at a volume flow rate of

    30 dm3/min, Pa (mm water column), max

    206 (21.0)

    – initial filter resistance to constant airflow at a volume flow rate of 95 dm3/min, Pa (mm water column), max

    820 (83.7)

    – filter breakthrough time measured by test substances, minutes, minimum:

    • cyclohexane at a concentration of (3.5 ± 0.4) mg/dm3

    90

    • hydrogen cyanide at a concentration of (5.6 ± 0.5) mg/dm3

    50

    • hydrogen sulfide at a concentration of (7.1 ± 0.7) mg/dm3 

    60

    • chlorine at a concentration of (15.0 ± 1.5) mg/dm3

    20

    • sulfur dioxide at a concentration of (13.3 ± 1.3) mg/dm3 

    20

    • ammonia at a concentration of (0.7 ± 0.1) mg/dm3

    120

    • mercury vapors at a concentration of (0.013 ± 0.001) mg/dm3

    100 h

    • nitrogen monoxide at a concentration of (3.1 ± 0.3) mg/dm3

    20

    • nitrogen dioxide at a concentration of (4.8 ± 0.4) mg/dm3

    20

    • carbon monoxide at a concentration of (6.2 ± 0.6) mg/dm3

    20

    • cyanogen chloride at a concentration of (5.0 ± 0.5) mg/dm3

    40

    • dimethyl ether at a concentration of (0.95 ± 0.1) mg/dm3

    30

    • isobutane at a concentration of (6.0 ± 0.6) mg/dm3

    25


    Storage

    VK-450 filters should be stored at −50°F to +120°F with maximum humidity not exceeding 98%. VK-450 filters should not be exposed to impact, hazardous gases or vapors. 

    CBRN Gas Mask Filter NBC-77 SOF 40mm Thread

    Due to a significant spike in demand, our lead times on all orders have been increased. There is currently a four-week lead time, and your order will be shipped in the sequence in which it was received. We appreciate your patience as we work through this. 

    The NBC-77 SOF filter canister, in combination with a full-face mask, mouthpiece assembly, or PAPR, reliably protects air passages against a wide range of harmful and highly toxic substances including all known CBRN agents.

    The filters are produced with standard round threads according to STANAG 4155 (EN 148- 1)- Rd 40×1/7″. The filter components are made of hard plastic. This results in a very robust product that is extremely durable against shock and impact damage in operational use.

    KEY FEATURES:

    • Compatible with standard 40mm NATO threaded respirators, which are widely available.
    • 20-year shelf life – save money long-term by not having to replace your filters every 5 years
    • Used by military personnel, CBRN specialists, and special operations forces all over the world
    • Filter all known CBRN agents, including radioactive iodine, rated for A2B2E2K2HgSXP3 D R.
    • Certified by European agencies and has the “CE” symbol. Compliant under EN 14387:2004 + A1:2008

     

    TECHNICAL DATABREATHING RESISTANCE IN PA BREATHING RESISTANCE IN PA
    Diameter110 mm@ flow rate 30l/min. EN 1) NBC-77 SOF 260 <140@ flow rate 95l/min. EN 1) NBC-77 SOF 980 <600
    Height85 mm
    Weight335 g ±5%
    Storage time20 years (factory sealed)
    TYPE AND CLASS PARTICLE FILTER EFFICIENCY @ FLOW RATE 95L/MPARTICLE FILTER EFFICIENCY @ FLOW RATE 95L/M
    A2 – organic gases and vaporsSX – CG, CK, PSSodium Chloride NaCl (S) Paraffin oil (L)EN 99,95 99,95NBC-77 SOF >99,999 >99,999
    B2 – inorganic gases and vaporsP3 – particles
    E2 – acid gases and vaporsD- dust
    K2 – ammonia and aminesR- reusable
    Hg – mercury vaporsREACTOR – radioactive iodine

    Note:
    1) Standard EN 14387+A1
    2) The filter was tested on dolomite dust clogging
    3) Radioactive iodine and its organic compound – methyliodide¹³¹ acc. to standard DIN 58621

     

    APPLICATION:

    The filter canister in connection with a suitable respirator or PAPR provides protection against solid and liquid particles, pepper spray (OC), smoke-producing substances, radioactive particles, bacteria and rickettsia, fungi, toxins, viruses, riot control agents (lachrymators, sternutators, vomiting agents), blister agents (vesicants), choking agents, blood agents, nerve agents, incapacitants, herbicides, pesticides, and TIC, such as bromoacetone, CS, CR, CN, CNC, CNS, CA substances, organic compounds of arsenic – diphenyldichlorarsine – CLARK I (DA), diphenylcyanoarsine – CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulphur mustard gas (HD), T-mustard gas, Q-mustard gas, nitrogen mustard gases (HN1, HN2, HN3), lewisite (L), mixed mustard gas (H-L), phosgene oxime (CX), phosgene (CG), diphosgene(DP), chloropicrin (PS), hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA), G-agents: sarin (GB), cyclosarin (GF), soman (GD), tabun (GA), IVA (GV), V-agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: fumes of organic or inorganic acids, hydroxides, organic solvents with a boiling point above 65° C, ammonia, amines, inorganic and acid gases, agricultural chemical combustion gases, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids, and organic substances, mercury vapors, radioactive iodine, organic compounds of iodine (Iodomethane, 129, 131), radioactive particles, etc.

    TESTING GASCONCENTRATION OF TESTING GASBREAKTHROUGH TIME IN MINUTES ENNBC-77 SOFDAC IN GRAMS NBC-77 SOF
    PPMMG/I
    A2CyclohexaneC₆H₁₂500017.5353920,475
    B2ChlorineCl₂500015204520,250
    Hydrogen SulphideH₂S50007.140>80>17,400
    Hydrogen CyanideHCN50005.625508,400
    E2Sulphur DioxideSO₂500013.320259,975
    K2AmmoniaNH₃50003.540505,250
    HgMercuryHg—–13 mg/m³100 hours>170 hours>3900
    SXCyanogen chlorideCICN25006.2820254,710
    ChloropicrinCCI₃NO₃500033.55204444,286
    PhosgeneCOCl₃500020.2420>77>47,058
    REACTORMethyloidide₁₃₁CH₃I2 hours>2 hours

     

    LIFETIME:

    Breakthrough time of a filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l/min, which is equivalent to the volume of air per minute used by an average person carrying out medium heavy work. The approximate lifetime (usage time) of a filter may, under normal conditions, calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.

     

    STORAGE AND MAINTENANCE:

    The filters are sealed in plastic bags by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30°C and relative humidity below 80%. Sealed filters tolerate also conditions of -30 to +50°C and RH below 95%. The storage period (month and year) for filters is marked on the filter label. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.

     

    DISPOSAL:

    After use, the filters are special refuse. Make sure that they are disposed of according to the filtered substance (gases or particles) in accordance with current waste treatment regulations. If the product is to be disposed of, it should be dismantled from the respirator and disposed of as solid waste. Please see local authority regulations for disposal advice and locations.

    Features

    air-flow

    AIR FLOW

    Constructed with air-flow mesh back panels to maximize ventilation and back support.
    water-resistant

    WATER RESISTANT

    Material that resists the penetration of water through the fabric.

    durable-water-repelent

    Durable water repellent

    A polymer substance applied to the face-fabric that helps to repel water and dries quicker.
    breathable

    BREATHABLE

    A fabric that allows the passage of air and moisture to keep you comfortable.
    moisture-wicking

    Moisture wicking

    Moisture-wicking fabric pulls sweat away from the skin to keep you dry and comfortable.
    anti-microbial

    anti-microbial

    Anti-microbial material inhibits the growth and reproduction of microorganisms or bacteria.

    anti-static

    ANTI-STATIC

    Anti-static material inhibits buildup of static electricity.
    natural-stretch

    Natural stretch

    Stretchable fabric for better articulation and/or gussets to maximize mobility and movement.
    hydration-compatible

    Hydration compatible

    Product with integrated hydration compartment to carry a hydration bladder.
    laptop-compatible

    Laptop compatible

    Product with built-in compartment for laptops

    concealed-carry

    Concealed carry

    Designed for more discreet or concealed method of carrying firearm.

    Colour Key